Upgrade Your Existing X-ray System with SpectralDR® Dual-Energy Imaging
Reveal™ 35C X-ray Detector
Reveal™ 35C is the world’s first single-exposure SpectralDR® detector, delivering dual-energy images — including standard DR, bone, soft-tissue, and high-/low-density imaging — in a single shot. Free from motion artifacts and workflow disruption, it supports portable and fixed X-ray applications across clinical and industrial environments, upgrading imaging performance without added dose or complexity.
Get More Insight from Every X-ray
Reveal™ 35C integrates seamlessly with existing X-ray systems, protocols, and workflows while expanding imaging capabilities through true single-exposure dual-energy imaging. Powered by SpectralDR® technology, it overcomes the limitations of traditional dual-energy systems by delivering multiple image types in one exposure, without motion artifacts, added dose, or additional hardware.
With a single exposure, Reveal™ 35C simultaneously produces standard DR images alongside material-differentiated views, including bone and soft tissue or high- and low-density imaging. This enables deeper insight across clinical, veterinary, and industrial applications, helping users visualize critical details that may be missed with conventional radiography.
Designed for both portable and fixed use, Reveal™ 35C supports general radiography, advanced diagnostic assessment, and demanding inspection environments. Its low-dose operation and intuitive workflow improve efficiency, reduce repeat scans, and support confident decision-making from one exposure.
Key Features
SpectralDR® technology:
1 exposure, 3 images, 0 motion artifacts
Cassette-size: 14 x 17 inch / 35 x 43 cm (ISO 4090) for seamless upgrade
Triple-layer detector design delivers a DQE of 67% at 1 lp/mm — up to 30% higher than typical DR panels.
True dual-energy subtraction through physics
Hot Swappable Batteries
Additional Downloadable Literature
Trusted by Users
Reveal™ 35C for Medical Applications
Why choose dual-energy (Spectral) X-ray?
SpectralDR® technology enables simultaneous acquisition of:
Standard X-ray
Soft tissue image
Bone image
—all from a single exposure using a standard X-ray dose.
Dual-energy images are clinically proven1 to:
Improve visibility of lung nodules, pneumonia, pneumothorax, and calcifications
Provide clearer identification of lines, tubes, and retained surgical objects
Improve image clarity without increasing dose or scan time
Reveal™ 35C: Evidence from Clinical Studies

33% more pneumonia cases found
compared to X-ray thanks to dual-energy images⁴

Increased confidence in 57% of ICU cases
thanks to dual-energy images with no added reading time⁵

43% more lesion visibility
when dual-energy images were included³

Up to 37% decrease
in the number of follow up CT scans for ICU patients9

Better visibility of lines and tube tips
without extra reading times⁵
Impact and ROI
Watch this interactive video to see how integrating dual-energy mobile X-ray could help reduce downstream imaging costs, support earlier, more confident diagnoses, and improve resource utilization in critical care settings.
Clinical Case
Reveal™ 35C with SpectralDR® technology brings dual-energy imaging to any compatible X-ray system. Whether in general radiography, emergency care, or critical care units, the ability to capture standard, bone, and soft tissue images in a single exposure works with your current protocols and workflow — then gives you the power to optimize based on your diagnostic needs.
Hidden Pneumonia Detection
A 51-year-old leukemia patient had a normal DR image. The soft tissue image revealed a focal opacity, later confirmed as pneumonia on CT, showing how dual-energy imaging can reveal findings standard X-ray may miss.
DR/SoftTissue Image

DR/ Soft Tissue Image
Visualization of calcifications
Lateral dual-energy bone image shows visible calcified coronary vessels, along with a PortoCath line, sternum, and sternal wire ties — all in a single exposure with Reveal™ 35C and SpectralDR® technology.
DR/Bone Image

Hidden mass Obscured by Degenerative Bone Disease
DR/SoftTissue Image

DR/ Soft Tissue Image
Better Line Placement Confirmation
Spectral dual-energy bone images provide clear visualization of vascular wire mesh and tube tips — without extra software, dose, or delay.
DR/Bone Image

Reveal™ 35C for Non-Destructive Testing (NDT)
SpectralDR® technology: supplemental subtracted images for better decision-making on the move
In addition to the DR, the SpectralDR® technology in the Reveal™ 35C detector offers quick access to supplemental dual-energy high-density and low-density images. No extra radiation is needed: all three images are created simultaneously with a single standard X-ray dose.
Maximize the potential of your mobile X-ray system, especially in challenging environments such as industrial sites, remote inspection locations, or applications requiring quick decisions. The extra details provided by single exposure dual-energy X-rays enhance decision-making, ensuring safety and efficiency.
Flexible Applications:
The Reveal™ 35C can be used in a range of fixed and mobile applications in the Non-Destructive Testing (NDT) field, including Industrial Inspection, Security, Aerospace, Electronics, and Construction. It’s fully compatible with legacy X-ray sources and techniques.




Reveal™ 35C: ASTM F792222-17 Compliant
The ASTM F792222-17 standard, established by the Transportation Security Administration (TSA), sets guidelines for the performance and testing of X-ray screening systems used in airport security. The standard covers various aspects, including image quality, radiation safety, system performance, and testing procedures. Compliance with ASTM F792222- 17 is crucial to ensure consistency and effectiveness in aviation security operations, safeguarding passengers, and air travel infrastructure against potential threats.
Reveal™ 35C for Veterinary Applications
SpectralDR® technology: supplemental subtracted images for better decision-making on the move
In addition to the DR, the SpectralDR® technology in the Reveal™ 35C detector offers quick access to supplemental dual-energy bone and soft tissue images. No extra radiation is needed: all three images are created simultaneously with a single standard X-ray dose.
Maximize the potential of your mobile X-ray system, especially in demanding environments like veterinary clinics and animal hospitals. Transporting animals can pose significant clinical and operational challenges, increasing the risk of stress and injury. Using a mobile dual-energy X-ray system helps mitigate these risks, ensuring safer and more efficient imaging for your veterinary patients.
Reveal™ 35C is the world’s first portable spectral X-ray detector. Thanks to its SpectralDR® technology, Reveal™ 35C X-ray detector overcomes the limitations of other dual-energy technologies, enabling bone and soft-tissue differentiation without motion artifacts in a single X-ray exposure. In other words, with one shot, the detector simultaneously delivers DR, bone, and tissue images. The Reveal™ 35C can be used in portable and fixed applications, providing veterinarians with invaluable clinical insights for informed decision-making. Reveal™ maintains low radiation exposure to the veterinary radiologist and the animal being imaged.
Our user-friendly innovative technology leads to improved outcomes for patients and practices. One exposure, three images, zero motion artifacts: why not?
Media Gallery






FDA 510(k) Clearance
Health Canada Medical Device Licence
CE Marking Under EU MDR
Contact us for availability in your region.
References:
Full Reference List
- Improved patient outcomes for dual-energy subtraction imaging:
1.1 (Lung Nodules) Oda, Seitaro, Kazuo Awai, Yoshinori Funama, Daisuke Utsunomiya, Yumi Yanaga, Koichi Kawanaka, Takeshi Nakaura et al. “Detection of small pulmonary nodules on chest radiographs: efficacy of dual-energy subtraction technique using flat-panel detector chest radiography.” Clinical radiology 65, no. 8 (2010): 609-615.
1.2 (Pneumothorax) Urbaneja, A., Dodin, G., Hoosu, G., et al. (2018) Added Value of Bone Subtraction in Dual-energy Digital Radiography in the Detection of Pneuomothorax: Impact of Reader Expertise and Medical Specialty. The Association of University Radiologists. Elsevier Inc.
1.3 (Pneumonia) Martini, Katharina, Marco Baessler, Stephan Baumueller, and Thomas Frauenfelder. “Diagnostic accuracy and added value of dual-energy subtraction radiography compared to standard conventional radiography using computed tomography as standard of reference.” PloS one 12, no. 3 (2017): e0174285.
1.4 (Tuberculosis) Sharma, Madhurima, Manavjit Singh Sandhu, Ujjwal Gorsi, Dheeraj Gupta, and Niranjan Khandelwal. “Role of digital tomosynthesis and dual energy subtraction digital radiography in detection of parenchymal lesions in active pulmonary tuberculosis.” European Journal of Radiology 84, no. 9 (2015): 1820-1827.
1.5 (Coronary Calcifications) Song, Yingnan, Hao Wu, Di Wen, Bo Zhu, Philipp Graner, Leslie Ciancibello, Haran Rajeswaran et al. “Detection of coronary calcifications with dual energy chest X-rays: clinical evaluation.” The International Journal of Cardiovascular Imaging (2020): 1-8.
- Maurino, S. L., Badano, A., Cunningham, I. A., & Karim, K. S. (2016, March). Theoretical and Monte Carlo optimization of a stacked three-layer flat-panel x-ray imager for applications in multi-spectral diagnostic medical imaging. In Medical Imaging 2016: Physics of Medical Imaging (Vol. 9783, p. 97833Z). International Society for Optics and Photonics.
- S. L. Maurino, K. S. Karim, V. Venkatesh. Diagnostic value of single-exposure dual-energy subtraction radiography in lung lesion detection: initial results. European Congress of Radiology-ECR 2022, 2022.
- Sanchez F, Kandel S, May M, Ronghe S, Rogalla P. Diagnostic value of dual-energy chest x-ray in immunocompromised patients to rule out pneumonia: initial results. European Congress of Radiology-ECR 2021, 2021.
- Rogalla P., Karim K. Added diagnostic value of portable dual-energy chest X-ray in a non-radiological reviewing environment. Radiological Society of North America-RSNA 2022, 2022
- Kuhlman, Janet E., Jannette Collins, Gregory N. Brooks, Donald R. Yandow, and Lynn S. Broderick. “Dual-energy subtraction chest radiography: what to look for beyond calcified nodules.” Radiographics 26, no. 1 (2006): 79-92.
- Manji, Farheen, Jiheng Wang, Geoff Norman, Zhou Wang, and David Koff. “Comparison of dual energy subtraction chest radiography and traditional chest X-rays in the detection of pulmonary nodules.” Quantitative imaging in medicine and surgery 6, no. 1 (2016): 1.
- Karim S Karim, “Single Exposure, Digital Dual-Energy Subtraction X-Ray Ushers in a New Era of Diagnostic X-Ray Imaging,” Radiology Management, Mar/Apr 2021.
- Venkatesh V., Patel N., Clarke K., Karim K. (2024). Implementation experience of a portable single exposure, dual energy X-ray detector for use in the ICU of a community hospital. American Society of Emergency Radiology Meeting.
- Rogalla P, Dos Santos JFP, Wintersperger BJ, et al. Opportunistic Identification of Coronary Artery Calcium and Valve/Vascular Calcifications on Chest X-Ray: Improvements With Single-Exposure Dual-Energy Imaging. Canadian Association of Radiologists Journal. 2024;0(0). doi:10.1177/08465371241291699
- Utarat Kaewumporn, MD, DMRD, Joel K.R. Samuel, MD,MBBS, Brian B. Ghoshhajra, MD, MBA, Nathaniel D. Mercaldo, Rajiv Gupta, PhD, MD, Michael H. Lev, MD, Michael Hood, MD. Accuracy ofdual-energy compared to standard chest X-ray for detection of coronary artery calcifications as an opportunistic screening tool. Radiological Society of North America-RSNA 2025,2025.
- Utarat Kaewumporn, MD, DMRD, Joel K.R. Samuel, MD,MBBS, Nathaniel D. Mercaldo, Rajiv Gupta, PhD, MD, Brian B. Ghoshhajra, MD, MBA, Michael H. Lev, MD, Michael Hood, MD. Performance of Dual-energy chest X-ray, compared to standard CXR and CT, for diagnosis of clinically confirmed coronary artery disease. Radiological Society of North America-RSNA 2025,2025.
Page last reviewed on October 9, 2025.
Upgrade What Your X-Ray Can Reveal
Reveal™ 35C expands imaging capabilities across clinical, veterinary, and industrial applications. Contact us to schedule a demo or learn more.